Recently active
Hello everyone,Does anyone have an idea how to resolve this error:CHECK_NRPE: Receive header underflow - only 0 bytes received (4 expected). Command:/usr/lib64/nagios/plugins/check_centreon_nrpe3 -H 10.192.30.9 -p 8084 -t 60 -u -2 -P 8192 -c check_centreon_plugins -a 'apps::backup::veeam::local::plugin' 'job-status' ' --filter-name="" --filter-start-time="" --filter-end-time="86400" --filter-counters="" --ok-status="" --warning-status="" --critical-status="%{is_running} == 0 and not %{status} =~ /Success/i" --warning-long="" --critical-long="" --verbose' Other commands are ok. NSClient++ version number/usr/lib64/nagios/plugins/check_centreon_nrpe3 -H 10.192.30.9 -p 8084 -t 60 -u -2 -P 8192I (0.5.2.41 2018-04-26) seem to be doing fine...
I am registering centreon2-centreon-datasource and it is presenting this problem So I can't insert the data to access the datasource I noticed that the grafana directory structure changed in this version
Hi the community,I’m currently experiencing a strange issue (don’t know exactly when it started).In the service tab, I can’t access the “Timeline” tab anymore for any service or host. I get the following error message Symfony\Component\HttpFoundation\Response::__construct(): Argument #2 ($status) must be of type int, string given, called in /usr/share/centreon/src/EventSubscriber/CentreonEventSubscriber.php on line 422In the centreon-error.log log file I saw this error[01-Mar-2023 16:29:02 Europe/Paris] CRITICAL: SQLSTATE[42S02]: Base table or view not found: 1146 Table 'centreon_storage.logs' doesn't exist {"context":"[object] (PDOException(code: 42S02): SQLSTATE[42S02]: Base table or view not found: 1146 Table 'centreon_storage.logs' doesn't exist at /usr/share/centreon/src/Centreon/Infrastructure/Monitoring/Timeline/TimelineRepositoryRDB.php:228)"}[01-Mar-2023 16:29:02 Europe/Paris] CRITICAL: Uncaught Error: Symfony\Component\HttpFoundation\Response::__construct(): Argument #2 ($sta
Hello,We are trying to setup the Windows SNMP plugin with the mode --process-count, but there is something wierd about the logic of this check.I would like Centreon to send a critical alert if the number of processes running matching my filter equals zero, but Centreon always returns OK./usr/lib/centreon/plugins/centreon_windows_snmp.pl --plugin=os::windows::snmp::plugin --mode=processcount --hostname=xyz --snmp-version='2c' --snmp-community='xyz' --process-name='xyz.exe' --critical='0'If the xyz.exe process is running this returns OK, but if the process is not running Centreon also returns OK.Reply when process runningOK: Number of current processes running: 1 | 'nbproc'=0;;0:1;0;Reply when process not runningOK: Number of current processes running: 0 | 'nbproc'=0;;0:1;0;Does it mean we cannot check a single process and return the status critical? Does it need to match at least two processes in order to send a critical status?Best regards,Lorenzo
Hello,I have a problem using REGEXP in the service widget to exclude bad services. When I use more than 256 characters, the screen goes blank, and I can't use more than 256 characters.Will an update resolve this issue? Is there any workaround?Thank you in advance for your help.Best regards,
Hello, I’m trying to install Centreon on my AWS cloud using AMIs `ami-04be5c2c7e9923780` (Oracle Linux 9) or `ami-081241b2722de973f` (Alma Linux 8) but I’m encountering issues during the web installation process.Firstly, we are encountering errors during the Centreon installation, such as "usermod: group centreon-engine does not exist," among others. Additionally, configuration files are not being created:ls -lrt /var/cache/centreon/config/engine/*ls: cannot access '/var/cache/centreon/config/engine/*': No such file or directoryls -lrt /var/cache/centreon/config/broker/*ls: cannot access '/var/cache/centreon/config/broker/*': No such file or directory This seems to be because Centreon does not support operating systems hardened by CIS compliances. The main purpose of my post here is to find out if others have encountered the same issue and if there is a known fix available. Additionally, I would like to inquire if the Centreon team plans to implement support for CIS-compliant OS.With g
Hello,Before we had a service that showed the free disk space on a disk, I deleted it to put a service per disk but I would like to put this service back, does anyone have its name?this is what i have this is what i want anyone can help please? Regards,
Hello, we hit the following error message in our logs, but do not understand the root cause and appropriate fix. ==> ./centreon-broker/central-broker-master.log <==[2024-02-22T12:34:51.765+01:00] [sql] [critical] sql: could not find index for service(1984, 46129) - maybe the poller with that service should be restarted Do you have any hint how to investigate ? Best Regards Olivier
Following a full /var and an enlargement of the FS, the poller does not restart the interface reports a database incident but I don't know in which log to find this error.Thank you for your help
Hi, I deleted hosts but i still have these entries on my services : How can i delete it from my admin page ?
Updated Centreon from 21.10.2 (CentOS 7) to 24.04.04 (Alma Linux 9) /usr/lib/centreon/plugins//centreon_ups_apc.pl \ -plugin=hardware::ups::apc::snmp::plugin \ --mode=battery-status \ --hostname=10.0.0.20 \ --snmp-version='1' \ --snmp-community='MY-SNMP' \ --replace-lasttime-format='' \ --warning-status='%{status} =~ /batteryLow/i' \ --critical-status='%{replace} =~ /yes/i' \ --unknown-status='%{status} =~ /unknown/i' \ --warning-load='' --critical-load='' \ --warning-voltage='' \ --critical-voltage='' \ --warning-current='' \ --critical-current='' \ --warning-temperature='' \ --critical-temperature='' \ --warning-time='' \ --critical-time='' \ --snmp-port=162 Port 161 UDP is used by Windows Server machine and port 162 APC SNMP Powerchute Bussines, I update to last version of agent too PowerChute Serial Shutdown 1.2APC agent detect connection:4/7/24 | 22:06:06 | SNMPV1: Nueva conexión realizada por el usuario MY-SNMP desde 10.
We have upgrade our fresh install of 22.10.1 to 23.04.0, after that we have issue exporting the configuration of poller server, everything it seem working but the “Uptime” is still the same before restarting/exporting poller configuration.We have tried to restart “gorgoned” on the poller and still the same uptime.We have tried with the following command on the poller:su - centreon-gorgone -s /bin/bash -c 'sudo systemctl restart centengine'With this command the uptime is resetted and it seem exported the configuration.
Upgrade 21.10.2 (CentOS 7) to 24.04.4 (AlmaLinux 9)No graph was generated until executing:Administration > Parameters > Data > Actions > Rebuild RRD Database
Hello everyone,I've installed my map server on a different machine from my mainframe. The configuration seems fine, but I'm having a problem accessing the map, so I need some help. ########## Centreon Map server version ########## [INFO] ii centreon-map-engine 23.10.3-bullseye amd64 Centreon Map service under Spring Boot framework########## System ########## [INFO] SELinux is not availableUnit firewalld.service could not be found. [OK] Firewall is disabled [INFO] Physical memory available on the server: 4013032 kb. [INFO] Number of CPU available on the server: 4 core(s)########## Java ########## [OK] Java 17 installed [OK] Optimization found for JVM: JAVA_OPTS="-Xms512m -Xmx4G -XX:+HeapDumpOnOutOfMemoryError -XX:HeapDumpPath=/var/log/centreon-map -Dmanagement.endpoints.enabled-by-default=false -Dmanagement.endpoint.health.enabled=true -Dmanagement.endpoint.metrics.enabled=true"########## Database connection ########## [OK] Connection to centreon [OK] Connection to ce
Hello,after upgrading from 19.10 to 23.10 i’m not able to restart centengine over the web interface on Central server. On poller is working ok. centengine restart from centreon-gorgone user is working i turn on debug on gorgone and this is output when i try restart centengine:“2024-07-03 16:12:14 - DEBUG - [legacycmd] Processing file '/var/lib/centreon/centcore//1720015930.4536-externalcommand.cmd_read'2024-07-03 16:12:14 - INFO - [legacycmd] Handling command 'RESTART', Target: '2'2024-07-03 16:12:14 - DEBUG - [legacycmd] internal message: [COMMAND] [0d765c1b11d6a95f44d356015d0f0c19f64c94902b908c17fd42c2c39a68fcc079d650295cbd7ac8c0177ab484586bb0d19a2fca5d6e1258c475f403045af3dc] [2] {"logging":0,"content":[{"metadata":{"centcore_cmd":"RESTART","centcore_proxy":1},"command":"sudo service centengine restart"}]}2024-07-03 16:12:14 - DEBUG - [core] Message received internal - [COMMAND] [0d765c1b11d6a95f44d356015d0f0c19f64c94902b908c17fd42c2c39a68fcc079d650295cbd7ac8c0177ab484586bb0d19a2fca5
For some reason, it looks like my ncpa check isn’t receiving the ncpa token from my macro. Check command looks like this:$USER1$/check_ncpa.py --performance --timeout=300 -t $_HOSTTOKEN$ -H $HOSTNAME$ -P 5693 -M plugins/check_updates -a '--assumeyes --no-boot-check -t 300'But it’s failing and then I look at the error, it looks as if _HOSTTOKEN isn’t being received. But when the check fails, I can see that the TOKEN value was not received. /usr/lib64/nagios/plugins/check_ncpa.py--performance--timeout=300-t-Hop.fs.corp-P5693-Mplugins/check_updates-a--assumeyes --no-boot-check -t 300I expect to see a *** next to the first -t option as I do on my other installations. This is a fresh install. Am I missing a step that perhaps I forgot about to allow this to work?If I hard code the value, it works fine but I have this working on other monitoring hosts.This install is the latest version on Rocky 9.
HelloIf you have problems with a Remote Server who is not in a stable state, like :wrong IP address or wrong name, in " Configuration > Pollers" strange information in "Monitoring > Resources Status" (graph error, Command line not showing)You can check the following thing :On the Remote Server, use the following request on the "centreon" database :SELECT `id`, `type`, `status`, `parent_id`, LEFT(`params`, 256), `created_at` FROM `centreon`.`task` ORDER BY `created_at` DESC LIMIT 10;Do the same on the Central.If you have some task in status "pending" so you have a synchronization problem between your Central and the Remote Server.On both RS and Centralcheck the local API reach-ability : curl "http://127.0.0.1/centreon/api/latest/"the command must return something like this :{"code":404,"message":"No route found for \"GET http:\/\/127.0.0.1\/centreon\/api\/latest\/\""}If you have something else, like an HTML answer, fix your Apache config to get this working.check the file :
Bonjour, J’utilise actuellement la version open source de Centreon et je cherche un moyen de mettre en place des seuils de latence maximale toléré et à ce que l’hôte passe en critical lorsque le seuil est dépassé. C’est pour de la supervision d’ip publique. J’ai vu qu’il y a le connecteur “Speedtest” qui répondrait surement à ma demande mais je me pause la question de si il est installable en ligne de commande sans payer de License Centreon avec tout les connecteurs et l’installation automatique. Et également si il existe d’autres moyens.Merci.
Hello,I am implementing the PostgreSQL plugin to check a database server, the version of PostgreSQL system is 9.4 and the plugin version is 3.0.15.I can’t have check result, it says :“UNKNOWN: Cannot connect: FATAL: aucune entrée dans pg_hba.conf pour l'hôte « xxx.xxx.xxx.xxx », utilisateur « centreonro »,base de données « postgres », SSL inactif”Is anyone met this before? Thank you in advance,Hassane
Hello The Watch,Here's the result of a synchronization control command from the WSUS plugin :OK: Current Synchronisation status is 'NotProcessing', Progress: 0.00% (0/0 items) - Last Synchronisation status is 'Succeeded', Duration: 3s | 'synchronisation_progress'=0;;;0;100 'last_synchronisation_duration'=3s;;;0;I want to use the ''synchronisation-status'' and ''last-synchronisation-status'' metrics which are text data in a dashboard but the metrics don't appear.Is this related to the fact that it's just text? Is there a solution?We plan to migrate to 24.04 in the coming months, we are currently on 23.10.11.Thanks for your feedback,Best Regards,
Hello everyone,J’ai installé centreon sur rhel 8, à l’étape ou je dois installé un serveur central j’ai utilisé “ l’Installation silencieuse d'un serveur central “, le soucis est que quand je me connecte sur l’interface web avec admin et le mot de passe généré, j’ai le mesage *Authentication failed*.Une idée ?
Hello everyone. I don’t know if what i want to do is in fact really hard, if i’m taking it by the wrong end, or if i’m simply missing something.I have a service that execute a shell script on my remote host. This script lists the 50 biggest cpu activ process and returns the users associated with it and how much cpu percentage each of them uses.When i look at the service graph i get kind of what i want, some curves representing each of these values.But when i want to add this supervision to my dashbord things become problematics. First i want to separate the two values that the service returns (numbers of active process and cpu utilization percentage) but this ultimately is not problematic as i can create a second service and divide the value between them.But when i want to add a widget to either my dashboard or customview. There are no widget that offer to monitor all of the metrics given by a service, i have to manually check the metrics i want included.The problem is that these metri
Since May 24, no data appears in the graph. (Centreon version 24.04.2).I’ve tried to upgrade centreon, restart server, clear caché…Many thanks in advance.
When I try to add a command check a got next message500 Internal Server Error Red Hat Enterprise Linux release 8.9 (Ootpa) + Centreon 24.04.3 This is a fresh installation and I tried reinstalling centreon but the problem is still thereNo evident errors in logs and I have issued “setenforce 0” and stopped firewalld too Finally I found an error in:/var/log/php-fpm/centreon-error.log [28-Jun-2024 16:25:27 America/Panama] [2024-06-28T16:25:27-0500] [CRITICAL] Uncaught Error: readdir(): Argument #1 ($dir_handle) must be of type resource or null, bool given {"exception":"[object] (TypeError(code: 0): readdir(): Argument #1 ($dir_handle) must be of type resource or null, bool given at /usr/share/centreon/www/include/configuration/configObject/command/DB-Func.php:308)"}
Hi, I’m an admin and Users on our Centreon 22.10 seems to not having access to the menu “edit my profiile” but I can’t find anything about it within the ACL. Is-it linked to the fact that they cannot edit users in the menu access ACL?Can someone explain to me how can I get this menu back for my customers ? Best regards,Pierre M.