/centreon_cisco_standard_snmp.pl --plugin=network::cisco::standard::snmp::plugin --mode=stack
is doing fine for physical stack switches.
We have some stackwise virtual switches in fine condition, but this check is showing up as ‘notredundant’.
old classical stack:
OK: Stack status is 'redundant' - Number of members waiting: 0, progressing: 0, added: 0, ready: 2, SDM mismatch: 0, version mismatch: 0, feature mismatch: 0, new master init: 0, provisioned: 0, invalid: 0, removed: 0 - All stack members status are ok | 'waiting'=0;;;0; 'progressing'=0;;;0; 'added'=0;;;0; 'ready'=2;;;0; 'sdm_mismatch'=0;;;0; 'version_mismatch'=0;;;0; 'feature_mismatch'=0;;;0; 'new_master_init'=0;;;0; 'provisioned'=0;;;0; 'invalid'=0;;;0; 'removed'=0;;;0;
.1.3.6.1.4.1.9.9.500.1.1.3.0 = 1
.1.3.6.1.4.1.9.9.500.1.2.1.1.3.1000 = 1
.1.3.6.1.4.1.9.9.500.1.2.1.1.3.2000 = 4
.1.3.6.1.4.1.9.9.500.1.2.1.1.4.1000 = 15
.1.3.6.1.4.1.9.9.500.1.2.1.1.4.2000 = 14
.1.3.6.1.4.1.9.9.500.1.2.1.1.5.1000 = 0
.1.3.6.1.4.1.9.9.500.1.2.1.1.5.2000 = 0
.1.3.6.1.4.1.9.9.500.1.2.1.1.6.1000 = 4
.1.3.6.1.4.1.9.9.500.1.2.1.1.6.2000 = 4
.1.3.6.1.2.1.47.1.1.1.1.7.1000 = Switch 1
.1.3.6.1.2.1.47.1.1.1.1.7.2000 = Switch 2
Member 'Switch 1' state is 'ready', role is 'master'
Member 'Switch 2' state is 'ready', role is 'standby'
new virtual stack:
CRITICAL: Stack status is 'notredundant' | 'waiting'=0;;;0; 'progressing'=0;;;0; 'added'=0;;;0; 'ready'=2;;;0; 'sdm_mismatch'=0;;;0; 'version_mismatch'=0;;;0; 'feature_mismatch'=0;;;0; 'new_master_init'=0;;;0; 'provisioned'=0;;;0; 'invalid'=0;;;0; 'removed'=0;;;0;
.1.3.6.1.4.1.9.9.500.1.1.3.0 = 2
.1.3.6.1.4.1.9.9.500.1.2.1.1.3.2 = 1
.1.3.6.1.4.1.9.9.500.1.2.1.1.3.500 = 4
.1.3.6.1.4.1.9.9.500.1.2.1.1.4.2 = 1
.1.3.6.1.4.1.9.9.500.1.2.1.1.4.500 = 1
.1.3.6.1.4.1.9.9.500.1.2.1.1.5.2 = 0
.1.3.6.1.4.1.9.9.500.1.2.1.1.5.500 = 0
.1.3.6.1.4.1.9.9.500.1.2.1.1.6.2 = 4
.1.3.6.1.4.1.9.9.500.1.2.1.1.6.500 = 4
.1.3.6.1.2.1.47.1.1.1.1.7.2 = Switch 1 Chassis
.1.3.6.1.2.1.47.1.1.1.1.7.500 = Switch 2 Chassis
Member 'Switch 1 Chassis' state is 'ready', role is 'master'
Member 'Switch 2 Chassis' state is 'ready', role is 'standby'
Can I manipulate the OID .1.3.6.1.4.1.9.9.500.1.1.3.0 = 2 in a way, that cswRingRedundant = 2 is ‘ok’?